Xinma STC series Three-phase exchange synchronous
STC series electric generator is suitable in the illuminations such
as village, town, building site, mountain area and pastureland etc
and the three-phase a.c. supply of motive force, and also can
regard to meet an urgent need the emergency power supply of
usefulness.
The electric generator for guards against drips a redeployment
type, and adopting the star shape with neutral of belt to come into
contact with the law, the specified line voltage is 400 volts, and
looking at and appraising voltage serve as 230 volts, frequency
50Hz,'s power factor 0.8 ( lag ). According to the needs, the 60Hz
and the electric generator of other voltage values also can be
provided.
The electric generator can directly join or connection with the
cone belt with prime mover, and is reversing specified(ly) to
continuous running. Working as prime mover rotational speed change
3% time, his permanent pressure function is fine to the wanton
change of load from 0-100%,cos1.0-0.8's scope, and at the same
time, need not any(ly) start equipping directly starting 0.7 times
of no-load asynchronous electrical machinery of squirrel cage mould
of capacity.
All windings adopt H's level enamel-insulated wire as well as H's
level insulant, and adopts the special epoxy resin vacuum to soak
technology as well as dampproofs, mould and the black lacquer
spraying processing technology of salt fog, the insulation grade of
winding fits grade requirement of H's. Corrosiveness air on his
insulation can defend damp and wet(ly) and fog, pollutant and
ocean.
The magneto PMG system which taken whichever especially suits in
the occasion that non- linear load and load frequently change.
The electric generator can run in the same direction as the hands
of a clock and against two kinds of directions on the hands of a
clock.
One bearing electric generator adopts the international standard
shaft coupling dish piece of general purpose SAE, and pledges that
the electric generator with one heart docks. Dock simply, and is
easy to safeguard. Drawing forth the thread by way of 12 main
stators comes into contact with the law to change, and can gain
arbitrary kind of voltage below the 600V.
Allocating advanced automatic voltage regulator AVR, who develops
by oneself possesses the higher reliability.
The main stator winding is 2/3 sections of distances, and
eliminated three harmonic of neutral current. A slot pitch in the
oblique slot of stator reduced the harmonic further.
All rotors all check as a result of the dynamic equilibrium. Two
fulcrum electric generators take half key to check.